Europlex 3GS Guia de Instalação

Consulte online ou descarregue Guia de Instalação para Teclados numéricos Europlex 3GS. Europlex 3GS Installation guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 87
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
INTRAMERICA SECURITY TECHNOLOGIES CORP.
50 VENTURE DRIVE, UNITS 6 & 7
TORONTO, ONTARIO, CANADA
M1B 3L6
TEL (416) 754-4313
FAX (416) 754-8992
INSTALLATION AND OPERATION MANUAL FOR
EUROPLEX
APLEX MODEL 3100E8
100-ZONE, 8-PARTITION
SUBSCRIBER'S CONTROL PANEL
© COPYRIGHT EUROPLEX LIMITED 1986
REVISED: APRIL 2000
FIRMWARE: A8E250/L8100E66
Vista de página 0
1 2 3 4 5 6 ... 86 87

Resumo do Conteúdo

Página 1 - APLEX MODEL 3100E8

INTRAMERICA SECURITY TECHNOLOGIES CORP. 50 VENTURE DRIVE, UNITS 6 & 7TORONTO, ONTARIO, CANADAM1B 3L6TEL (416) 754-4313FAX (416) 754-8992E-MAIL geo

Página 2

8MOUNTING THE PANEL AND WIRING THE SYSTEMLocate the panel in an area that has convenient access and then fasten the panel securely to awall at about c

Página 3

9MOUNTING THE PANEL AND WIRING THE SYSTEM cont.WIRINGZones 1 through 100 are connected using D-LEMs, Q-LEMs, or COMBO LEMs. Determinewhether it is mor

Página 4

10TERMINAL CONNECTIONSTERMINAL OPERATION/FUNCTION 1 Remote Buzzer -ve Switch 2 +12 VDC (Fused at 1.25 amp, Fuse F2) 3 Spare No Connection 4 Spare

Página 5 - 8(SPACE) %

11Terminal 1 is a switched-negative output. Whenever the panel piezo-sounder is beeping, a quadDarlington-transistor integrated circuit (ULN 2004) swi

Página 6

12Terminal 27 is the LMTC (LEM-line) data line returning a series of nominally 6-volt pulsesfrom the LEMs to be decoded by the panel.Terminals 30 and

Página 7

13Terminal 40/J24/J26 is the receive line for incoming data [e.g., DVACS(tm), auto-dial modem,etc.]. In non-polled applications (e.g., logging printe

Página 8

141020 DUAL LEMMODEL 1020 DUAL LEM (D-LEM)The Model 1020 Dual Line Encoder Module (D-LEM) is used to multiplex two devices (e.g., adoor contact, a

Página 9

15MODEL 1020 DUAL LEM (D-LEM) contThe D-LEMs may be placed in any order and in any position on the cable. There is no restrictionon the distance betwe

Página 10

162. The coding table on page 26 shows the DIL switch settings for D-LEMs, C-LEMs, andCOMBO LEMs. (Refer to page 23 for information on C-LEMs.) The ma

Página 11

17LOOP-WIRING CONFIGURATIONSEach Model 1020 D-LEM provides for two separate zone input loops to be connected. EffectiveL mid-1995, for ULC-listed inst

Página 12

GENERAL INFORMATION ... 1KEYBOARD ...

Página 13

18LOOP-WIRING CONFIGURATIONS cont. Circuit Wiring for Non-ULC Listed InstallationsNote that the following wiring method is not suitable for ULC-liste

Página 14

19LOOP-WIRING CONFIGURATIONS cont. Circuit Wiring for ULC-Listed InstallationsUse Form C contacts and 4,300-ohm (yellow-orange-red) resistors to prov

Página 15

20LOOP-WIRING CONFIGURATIONS cont.Circuit Wiring for ULC-Listed Installations cont.To series-connect three or more Form C devices, install the 4K3-ohm

Página 16

211024 REV 1.0 QUAD LEM1024 REV 1.0 QUAD LEM (Q-LEM)The Model 1024 Rev 1.0 Quad Line Encoder Module (Q-LEM) features four input-loopconnections and a

Página 17

221024 REV. 2.1 QUAD LEMMODEL 1024 REV 2.1 QUAD LEM (Q-LEM)The Model 1024 Rev 2.1 Quad Line Encoder Module (Q-LEM) features four input-loopconnections

Página 18

231101 C-LEMMODEL 1101 COMMAND LEM (C-LEM)L The Model 1101 Command Line Encoder Module (C-LEM) is a remote switching module thatmay be installed anywh

Página 19

24MODEL 1101 COMMAND LEM (C-LEM) cont.Terminals 1, 3, 4, 9, 11, and 12 are connected exactly as for D-LEMs. Terminals B or F require+12 volts DC, whil

Página 20

251121 COMBO LEMMODEL 1121 COMBINATION LEM (COMBO LEM)The Model 1121 Combination Line Encoder Module (COMBO LEM) features one D-LEM andone C-LEM combi

Página 21

26MODEL 1020 D-LEM, 1101 C-LEM, AND 1121 COMBO LEM CODING TABLE ZONE NUMBER VS. D-LEM/C-LEM/ TERM. STRIP SCREWS COMBO LEM DIL

Página 22

27 ZONE NUMBER VS. TERM. STRIP SCREWSQUAD LEM REV 1.0QUAD LEM REV 2.1 Q-LEM DILADDRESS SWITCH #TERM. NO. 5 7 8 10 TER

Página 23

1GENERAL INFORMATIONThe APLEX Model 3100E8 is a microprocessor-based, subscriber's control panel that canmonitor a maximum of 100 zones, all of w

Página 24

28 PANEL OUTPUTSIncluded in the basic panel are seven outputs: three SPDT relays and four switched-positive,current-limited voltage outputs. The relay

Página 25

29OUTPUT ASSIGNMENT cont.PANEL/C-LEM PANEL TERMINAL FUNCTIONOUTPUT NO. SCREW21 - Area 1 Armed, C-LEM 2122 - Area 2 Armed, C-LEM 2

Página 26

30ZONE TYPESAs received from the factory, all 100 zones in the panel are programmed as instant-acting,AREA-1 intrusion zones. Unless indicated, the zo

Página 27

31AREA-8: This is a normally closed, instant-acting, intrusion zone type for area 8 of the system. When area 8 is armed, a violation of this zone wil

Página 28 - MODEL 1024 Q-LEM CODING TABLE

32area armed. If all areas are to be armed at the same time using the FULL ARM key, then the exittime will be that programmed for the Full Arm Ex Time

Página 29

33ZONE TYPES cont.TECH: This zone type is used to provide supervisory monitoring of non-burglary conditionsL (e.g., freezer monitor, boiler flame-out,

Página 30 - L 9 - Panic, C-LEM 9

34ZONE TYPES cont.FOLWR1: This normally closed zone type is used to provide protection along the exit and entrypath(s) between the control panel or th

Página 31

35POWERING UP THE PANELINITIAL ACTIVATION OF THE PANELThe control panel as received from the factory has been given a COLD START and all settingswill

Página 32

36The display will now show COLD START and, in another two seconds, PROM CHKSUM=nnnnH. The piezo-sounder will beep. Press the RETURN key to contin

Página 33

37POWERING UP THE PANEL cont.Loop states are categorized as:DISCON - Loop open circuited. Loop resistance = infinityOPEN - Alarm contact open. Loop

Página 34

2GENERAL INFORMATION cont.modes directly into the system. There are 20 keys on the keyboard, 19 of which have 3 letters,characters, or numbers. This a

Página 35

38POWERING UP THE PANEL cont.AUTO STARTThe panel contains a "watch-dog" timer. Should there be a major disturbance to the hardware(e.g., ele

Página 36

39PROGRAMMING THE PANELFUNCTIONS AND MODESThere are 25 functions or modes available in the control panel. Access to these by each of the 248general us

Página 37

40Some functions or modes are self-completing (i.e., they exit automatically). Others will requirefurther action. For the SET DATE/TIME and SET TIME C

Página 38

41PROGRAMMING THE PANEL cont.in DISARM mode, the date and time will alternate with a display of any zones that are open (inalarm). If a zone descripti

Página 39

42PROGRAMMING THE PANEL cont.YES key to make a hard-copy record of the system log. While the printing is in progress, thedisplay will show PRINTING S

Página 40

43PROGRAMMING THE PANEL contthis mode. As the exit occurs, the panel beeps and then briefly displays the number of shunts inplace. To exit at any time

Página 41

44PROGRAMMING THE PANEL cont.SINGLE-ZONE MONITOR - This option allows the user to examine any zone and display itsstate and analogue value. Once the z

Página 42

451. In the SINGLE-ZONE MONITOR option, if a 2K2-ohm resistor is connected between terminals 6 and 7, the display will show AREA-1 5 CLOSED [2

Página 43

46IDS (IDENTIFICATION CODES) - To select or change identification codes (IDS), press theFULL DISARM key. The panel will display ENTER USER NO. 1. If

Página 44

47allow this general user to disarm the panel, press the RETURN key. The flashing NO willremain and the next option will follow. If this option is t

Página 45

3A ! YES !B : NO XC .FULL DISARM +D , AUDIBLE

Página 46 - DISCON Continuous

48RETURN key; otherwise, enter the number of the required zone and then press the RETURNkey. The display will then show a flashing cursor, /\, in the

Página 47 - SHORT 0 21 3

49EXIT-4 TIME 30: If an EXIT-4 zone type has been assigned, this variable sets the amount ofexit and entry delay time allowed for exit from and

Página 48

500 - The bell relay will reset after the bell time expires and will not retrigger on any further zone violations.1 - The bell relay will reset a

Página 49

51PROGRAMMING THE PANEL cont.SYSTEM VARIABLES RECHECK:When the SUPVRY SHUTDOWN 0 variable is displayed, press the AUDIBLE SILENCE 1 (-)key to che

Página 50

52PROGRAMMING THE PANEL cont.(IMMEDIATE) COMMAND MODE ( I key): This mode is used by the serviceperson toprogram a command that will be executed by th

Página 51

53PROGRAMMING THE PANEL cont.changed by pressing the YES key. Use the FULL DISARM (+) key to advance to the next outputand the AUDIBLE SILENCE 1 (-) k

Página 52

54L The display will show COMMS MODE 0. The following chart summarizes the choices:0 - Used in a polled environment (e.g., DVACS(tm) , PANELMA

Página 53

55The display now shows SYSTEM ID 0. This is the APLEX polling address and is used whencommunicating with the EUROPLEX Model 1431/1432 autodial mod

Página 54

56LOG DATA TYPE SELECT 1 - Zone activations 1 2 - Status changes 2 3 - User actions 4 4 - Output switching 8 5 - Variable va

Página 55

57enter a 1. If you wish to have the panel dial back to you after you have previously establishedcontact with the panel, enter a 2. Press the RETURN k

Página 56

4The keys described above will be referred to in this manual by the names shown in the left-handcolumn on the previous page. The cursor is normally a

Página 57

58If access mode 2 (the dial-back option) was chosen above, the display will now show ENTERDIAL-BACK NUM, followed in a moment by a blank screen. Ente

Página 58

59PROGRAMMING THE PANEL cont.is used and ** INVALID ENTRY ** will be displayed if the correct format is not used. Thedisplay will show ENTER DAY NO.

Página 59

60QUICK PROGRAMMING GUIDEThe following section provides a quick summary of the programming procedure for the APLEXModel 3100E8 8-area control panel. I

Página 60

61DISARM). The panel will display a flashing sub-menu: IDS--OPTIONS-NAMES.IDS (IDENTIFICATION CODES) - To select or change identification codes (IDS),

Página 61

62listed below. The AUDIBLE SILENCE 1 (-) key may be used to return to a previous option. Toexit from this option, press the NO key whenever the displ

Página 62

634 (Exit-1 Time, Exit-2 Time, etc., see pages 48 to 49) and, if applicable, the entry delay time forthe common area (C-Exit Time), see page 48. Note

Página 63

64and alarm outputs for each individual area. These dry contacts may be used to show area statuson an LED display or to allow the system to be monitor

Página 64

65OPERATING THE PANELThis section details the functional operation of the panel when it is armed and disarmed. Additional information about some other

Página 65

66In addition, when an individual area is disarmed, the common area is disarmed automatically andthe armed output C-LEMs (if used) for both that area

Página 66

67ADDITIONAL NOTES CONCERNING PANEL OPERATIONL DURESS ALARM FEATURE - A Duress alarm feature is available that will allow the user totransmit a duress

Página 67

5OPERATING CONVENTIONSThe following is a brief summary of how to select a function or mode, how to perform variousfunctions, and how to exit from a se

Página 68

68NOTES CONCERNING THE MODEL 1431/32 AUTO-DIAL MODEMSAUTO-DIAL MODEMSThis section describes the connection and operation of the Model 1431/32 Hayes(tm

Página 69

69NOTES CONCERNING THE MODEL 1431/32 AUTO-DIAL MODEMS cont.1431/1432 APLEX MK2J BlockAPLEX MK3J BlockAPLEX MK4Comms PortMIDIPLEXJ BlockDIRECTPLEXRx J2

Página 71

71NOTES CONCERNING THE MODEL 1431/32 AUTO-DIAL MODEMS cont.The SET DATA FORMAT function allows the panel communications port to be configured forconne

Página 72

72NOTES CONCERNING THE MODEL 1431/32 AUTO-DIAL MODEMS cont.For example: Suppose that only read commands (read zone states, read output states) and wr

Página 73

73NOTES CONCERNING THE MODEL 1431/32 AUTO-DIAL MODEMS cont.immediately and any logged data will be sent to the remote printer. When all the data is se

Página 74

74NOTES CONCERNING THE MODEL 1431/32 AUTO-DIAL MODEMS cont.commands, consult any commercial auto-dial modem manual. Press the RETURN/ENTER keyto proce

Página 75

75NOTES CONCERNING THE MODEL 1431/32 AUTO-DIAL MODEMS cont.to a 7-bit word, the parity is automatically set to even).The display may now show BAUD RAT

Página 76

76NOTES CONCERNING THE MODEL 1431/32 AUTO-DIAL MODEMS cont.CALLING IN TO THE CONTROL PANEL: Any time the Model 1431/1432 auto-dialmodem is powered up

Página 77

77NOTES CONCERNING DVACS(tm) TECHNOLOGYDVACS(tm) - DIGITAL/VOICE ACCESS and CONTROL SYSTEMWhere the service is provided, the APLEX control panel may b

Página 78

6INSTALLATION PLANNING GUIDE AND CHECKLISTInstallation of the system involves mounting and wiring the control panel, configuring the system,and finall

Página 79

78minutes (900 seconds), then the message will disappear 15 minutes after it is first turned on].Press the HELP key twice again and the process will r

Página 80

79If your customer has been using a local printer and has lost the use of it because of DVACS(tm) operation, then you may install a Model 3302R3 port

Página 81

80LIBRARY MESSAGES cont.HEX DECIMAL LIBRARY MESSAGE CONTEXT U=User Selection, S=StatusCODE CODE Alert, - = Not Transmitted3E 62 DOOR F

Página 82 - LIBRARY MESSAGES cont

81LIBRARY MESSAGES cont.HEX DECIMAL LIBRARY MESSAGE CONTEXT U=User Selection, S=StatusCODE CODE Alert, - = Not TransmittedC2 194 COMMS

Página 83

82INDEXAAC POWER 8ACCESS CONTROL VALUE 55, 71, 77ACCESS MODE VAR 56, 73ACKNOWLEDGE ALARMS FN. 40ACKNOWLEDGING 40, 66ADDRESS 9, 35, 54, 58ADDRESS VALUE

Página 84

83INDEX cont.DDUAL LEM 2, 14-16, 25DURESS ALARM FEATURE 50, 67DVACS(tm) 77-79EEDITING 4, 51, 63ENABLE DURESS VAR. 50END-OF-LINE RESISTOR 17, 19-20, 33

Página 85

84INDEX cont.LLOG DATA LOSS 38LOG DATA TYPE 56LOG FILTER VALUE 56, 72, 77LOG OUTPUTS VAR. 49LOG, PRINT 41LOOP STATES 37LOOP WIRING 14, 17-20, 21, 22

Página 86

85INDEX cont.SSECURITY 1, 5, 40, 46SERIAL-INPUT PRINTER 12, 13, 41, 43, 53, 54-56, 58, 71-74, 78-79SERVICE MODE MODE 43SERVICE USER 1, 39, 46, 47SET

Página 87

76. SET THE NUMBER OF AREASThe system can be partitioned into a maximum of eight areas. Each area is like a mini-panel andcan be armed, disarmed, etc.

Comentários a estes Manuais